22 and it worked ok i turned it on the other day and it run for a little then it quit. it is like it has no power what and were can i check for power jim
Pool & Spa - Teledyne Laars - Laars Lite 2 Pool Heater 325,000 Btu / Natural Gas
1st place i would check is pressure switch.this component is number 1 in failure frequency.depending on your model,it is either screwed into in/out header or behind front panel. check for continuity(with pump running) using multi-meter.
Answers & Comments
1st place i would check is pressure switch.this component is number 1 in failure frequency.depending on your model,it is either screwed into in/out header or behind front panel. check for continuity(with pump running) using multi-meter.