Sounds like you need a bigger fuse.What happens is there is no load (air) in the tank so their is no compression and the motor isn't working as hard as when it reach's the cut off point and restarts.Now there is air in the tank which makes the motor work harder and that pulls more than 15 amps and blows the breaker.I would start with a 30 amp and go higher if need be.Thank You for choosing FixYa.com
I always add this for your information. If this is not the solution that you are looking for please re post because when we pick a question to answer FixYa takes it out of the questions.
Answers & Comments
Sounds like you need a bigger fuse.What happens is there is no load (air) in the tank so their is no compression and the motor isn't working as hard as when it reach's the cut off point and restarts.Now there is air in the tank which makes the motor work harder and that pulls more than 15 amps and blows the breaker.I would start with a 30 amp and go higher if need be.Thank You for choosing FixYa.com