Amana ned7200tw10 intermittent heating problem. New heating coil installed but dryer does not always run through heating cycle. Codes that come up are 2 and 10 when in diagnouses mode
Sensors may be coated with waterproof wax from dryer sheets. Wash them with windex. The dryer not sensing moister it THINKS them clothes it dry. Cleaning the sensors works. Try it. The sensors will be behind the filter wall just below the filter on most sensor type dryers.
If you need further help, reach me via phone at https://www.6ya.com/expert/dan_73bbd84fe1d95b61
I tryed this and still will only drying cloths once and awhile, I replaced thermister,dryer electric coils and rechecked the codes again and 2 shows up again in diagnous mode. what could it be?I tryed this and still will only drying cloths once and awhile, I replaced thermister,dryer electric coils and rechecked the codes again and 2 shows up again in diagnous mode. what could it be?
Answers & Comments
Sensors may be coated with waterproof wax from dryer sheets. Wash them with windex. The dryer not sensing moister it THINKS them clothes it dry. Cleaning the sensors works. Try it. The sensors will be behind the filter wall just below the filter on most sensor type dryers.
If you need further help, reach me via phone at https://www.6ya.com/expert/dan_73bbd84fe1d95b61
I tryed this and still will only drying cloths once and awhile, I replaced thermister,dryer electric coils and rechecked the codes again and 2 shows up again in diagnous mode. what could it be?