Aprilaire 550 makes extremely loud grinding noise when turned on
Bought a home that has a furnace with aprilaire 550. Furnace works ok. I changed the water wick in the humidifier and turned it on - it makes a loud grinding noise. after a minute or so it went away and water stopped. sincce then, every few minute it seems to kick in with extremely loud grinding noise - the wick seems wet though.
This being bypass filter should I just replace solenoid? if so how do I do it? ( I don't think I saw any fan in there it is not a powered model if I read correctly)
thx for your help.
Humidifiers - Aprilaire - 550 Humidifier
Answers & Comments
Yes it should be bypass but solenoid could be trying to open but the voltage to it may be to low if you have 24v ac power at the 2 small wires. but to change shut down power to furnace and water to humidifier.you loosen the 2 compression nuts unwire they cant be reversed so dont worry then 2 mounting screws then reverse to install