What breaker? The breaker for the condenser? Likely have a compressor shorted to ground or drawing locked rotor amps. Easiest way to tell is make sure breaker off, unhook compressor wires from contactor. Turn on breaker and turn on machine. If the breaker does not trip, obviously problem with compressor
If you need further help, reach me via phone at https://www.6ya.com/expert/thomas_092728000e6acb79
Answers & Comments
What breaker? The breaker for the condenser? Likely have a compressor shorted to ground or drawing locked rotor amps. Easiest way to tell is make sure breaker off, unhook compressor wires from contactor. Turn on breaker and turn on machine. If the breaker does not trip, obviously problem with compressor