CS Code Got a CS code, checked things out and found the upper magnatron was bad, burned a hole in the air duct. Replaced the magnatron, still get a CS code after 5 secs or so. I tested and checked the lower magnatron and it seems to work fine. Not sure why its cutting off after a few secs. Any thoughts work be great. Thanks, Frank Monteleone 914.646.8105 Got a cs code ,was able to clear the code by un plugging for 5 sec.The problem is the panel lights come on ,the timer works ,but the top fan does not come on and the microwave does not heat.I did change the interlock door switch,still does not heatup