Had an FL4 error code and in-line fuses were blowing, replaced the R0367100 igniter (old one missing the tip) and fuses, but still blowing the 2 fuses and getting the 04 code
No more details that would
Pool & Spa - Jandy - Laars Lite 2 Pool Heater 125,000 Btu / Propane Gas
Answers & Comments
Make sure the wiring is correct then take fenwall off turn around to see if burned spot where ignitor wires go in sometimes the ignitor will take out the fenwall shorting it out so you will keep going through ignitors