Have Miler Trailblazer 302.. it will start but wont weld and the outlets dont work either.. what could be the problem?
Set it on high idle and "dug" the welding rod into ground clamp and only see tiny flickers of spark
Welding Tools - Miller - Trailblazer 302 Welder Generator 907217 907216
Answers & Comments
Switch S1 may be dirty or damaged. The field should not need flashing as that will occur when you engage the start button.
It is possible there are some faulty connections in the 24 volt control section. Loose or corroded 24 volt connections to the contactor may not be allowing adequate current to flow. The connections on the SR 1 board should be checked as well. Also check the rectifiers. THey should be moderately high in resistance with test leads held one way on the rectifier, then with leads reversed, the resistance should be at a minimum 10 times different than the first reading either greater or lesser. Use a decent DMM to test them.