HDP600 print ribbon will not align properly. Using the diagnostics section, the color ribbon, ymckk, will not align to its correct starting point so that an accurate id card can be produced. The data is spread across the color panels at various starting points, failing to initialize and sense that the ribbon is in the correct starting point. Not receiving a bad sensor error message
If card image is spread out into the yellow panel and the next magenta panel ...and so on skiping panel of the ribbon, then is defenitlly a sensor mis calibration problem. Check if you working in a place where to much natural light is present. The printer needs to detect the diffrent colors of the ribbon panels to print without skkiping them. re-calibrate the sensor. also as to "see or sense" the timing white marks on the ribbon that separates each panel.
Answers & Comments
If your looking for a new unit www.getthatpart.com has them at a very good price ($2,500.00)brand new sealed in box
If card image is spread out into the yellow panel and the next magenta panel ...and so on skiping panel of the ribbon, then is defenitlly a sensor mis calibration problem. Check if you working in a place where to much natural light is present. The printer needs to detect the diffrent colors of the ribbon panels to print without skkiping them. re-calibrate the sensor. also as to "see or sense" the timing white marks on the ribbon that separates each panel.
I hope i help
[email protected]