Heater will not stay lit
The heater worked great when I first bought it.
Now it will not stay lit. As soon I release the lit button
The unit goes out. I could not find the manual to check
On anything. I would appreciate a manual for it.
It is a RLP40.I have not got a chance to use it
Only tried it after I bought it. I bought it at Home Depot
In Waterville Maine.
Thank you
George
Heating & Cooling - Reddy - Heater-30,000 BTU Propane Forced-Air Heater
Answers & Comments
Leave automatic button depressed for 30 seconds after flame ignites.