Hi, I have a Kipor sinemaster 1000 generator that has been in storage for a few years added fresh fuel and engine started. The 12v dc works however when I plug an appliance in the main power plug there is no power even though the green output led is lit. Anyone know what is wrong thanks
The DC output for battery charging is from the engine alternator and is completely independent from the generator inverter.
As this is an inverter unit the typical polarization techniques for standard generators will not apply.
The ouput indicator being lit means the inverter input output should be good. This further implies a circuit disconnect state at the outlets. Try pressing the overload reset switch to make sure it is not in an odd state.
Answers & Comments
The DC output for battery charging is from the engine alternator and is completely independent from the generator inverter.
As this is an inverter unit the typical polarization techniques for standard generators will not apply.
The ouput indicator being lit means the inverter input output should be good. This further implies a circuit disconnect state at the outlets. Try pressing the overload reset switch to make sure it is not in an odd state.