To connect power cord: • Remove the screws from the cover of the junction box located at the top rear of the dryer. • Loosen/remove the two screws on the strain relief clamp and remove from 4-wire supply cord. • The strain relief splits into two indentical parts. • Insert the large flange of both sections into the hole located on the left side of the junction box housing. The short flange of both sections and screws must remain positioned on the external side of the junction box housing. • Insert the 4- wire supply cord through both sections of the strain relief and re-install strain relief screws, do not fully tighten until electrical connections are complete. • Attach the power cord ground conductor (green wire) to the ground terminal marked with the ground symbol. Tighten screw until ground conductor is secure. (See Fig. 7) • Attach the power cord neutral conductor (white wire) to the neutral terminal. (marked N) Tighten screw until neutral conductor is secure. (See Fig. 7) • Attach the power cord phase conductor (black wire) to the phase terminal (marked L3). Tighten screw until power conductor is secure. (See Fig. 7) • Attach the power cord phase conductor (red wire) to the phase terminal (marked L1). Tighten screw until power conductor is secure.(See Fig. 7) • Tighten the screws on the strain relief so that the power cord cannot be moved. • Re-install the cover of the junction box and secure with four screws removed earlier. • The dryer is now ready to be connected to the power supply receptacle.
This is from the manual for the Danby DCD5505W. You did not give the model # so I went off of what you listed it under.
Good Luck and please rate 4 thumbs for the free answer.
Answers & Comments
To connect power cord:
• Remove the screws from the cover of the
junction box located at the top rear of the dryer.
• Loosen/remove the two screws on the strain
relief clamp and remove from 4-wire supply
cord.
• The strain relief splits into two indentical parts.
• Insert the large flange of both sections into the
hole located on the left side of the junction box
housing. The short flange of both sections and
screws must remain positioned on the external
side of the junction box housing.
• Insert the 4- wire supply cord through both
sections of the strain relief and re-install strain
relief screws, do not fully tighten until electrical
connections are complete.
• Attach the power cord ground conductor (green
wire) to the ground terminal marked with the
ground symbol. Tighten screw until ground
conductor is secure. (See Fig. 7)
• Attach the power cord neutral conductor (white
wire) to the neutral terminal. (marked N)
Tighten screw until neutral conductor is secure.
(See Fig. 7)
• Attach the power cord phase conductor (black
wire) to the phase terminal (marked L3).
Tighten screw until power conductor is secure.
(See Fig. 7)
• Attach the power cord phase conductor (red
wire) to the phase terminal (marked L1).
Tighten screw until power conductor is
secure.(See Fig. 7)
• Tighten the screws on the strain relief so that
the power cord cannot be moved.
• Re-install the cover of the junction box and
secure with four screws removed earlier.
• The dryer is now ready to be connected to the
power supply receptacle.
This is from the manual for the Danby DCD5505W. You did not give the model # so I went off of what you listed it under.
Good Luck and please rate 4 thumbs for the free answer.
Hi and Welcome to FixYa. I am Kelly. Here is a l;ink with pictures of what it should look like once installed.
http://repair2000.com/cord.html
Black to the left post
White to center post
Red to right post
Green to the chassis ground.
Thanks for using FixYa,
Kelly