I am turning power on to my Minimax NT but the screen only reads "Off" and will not turn on. I have never had to do anything but turn on my breaker to the unit. Not sure what to do???
1st check the thermistor, it is plugged into the back of the circuit baor on the inside of the door, It will have either two small white wires ,or it may have two yellow wires. Pluu the plug from the circuit board, wet your finger and touch the two terminals on the board with the wet finger. IF this doe not work most likely is the circuit board.
Answers & Comments
1st check the thermistor, it is plugged into the back of the circuit baor on the inside of the door,
It will have either two small white wires ,or it may have two yellow wires.
Pluu the plug from the circuit board, wet your finger and touch the two terminals on the board with the wet finger. IF this doe not work most likely is the circuit board.
no,
if it was not recieving propane this would not read off on the display but it would go into lockout after 3 failed ignition attempts.