I have a 1985 cr500 with no spark . i have replaced the stator, pickup coil, cdi, and had the coil tested . i have check all wiring , grounds, has new plug. any thoughts on what the problem is??
Check your wiring for a short (or an open circuit) on the emergency stop/kill switch. It is an '85, so a wire that has rubbed through the outside protection could have grounded out.
Ign module mite b bad...or batt tu..u need 12.6v always fora coil ignition. If it has a kik startr ucan replace batt w a capacitor calld a battery eliminator..turns it to magneto. Getta clymer shopbook please
Answers & Comments
I tend to agree with the comment that you might have a short in your Killswitch.
Check your wiring for a short (or an open circuit) on the emergency stop/kill switch. It is an '85, so a wire that has rubbed through the outside protection could have grounded out.
Cr500 doesnt have a battery ?? replace the coil. Youve come this far. Ive seen coils test ok and not work.
Ign module mite b bad...or batt tu..u need 12.6v always fora coil ignition. If it has a kik startr ucan replace batt w a capacitor calld a battery eliminator..turns it to magneto. Getta clymer shopbook please