The fusing temperature does not reach 175C degrees within 30 sec of turning on the power, or the fusing temperature keeps at 140C degrees.
C/I/0/I code 14. If it doesn't reset probably a blown thermostat on those piece of **** fusers. Also have seen the lamps some, mostly thermostat. If it has many miles on it I'd just replace the fuser.
If the previous methid wont work..., Clear --> Density select --> Clear --> Density select is for service mode. Check code 26-30 and set to 0 - CE mark support control OFF Try surge arrest power source.
Answers & Comments
H4 00 Heat roller abnormally low temperature
The fusing temperature does not reach 175C degrees within 30 sec of turning on the power, or the fusing temperature keeps at 140C degrees.
C/I/0/I code 14. If it doesn't reset probably a blown thermostat on those piece of **** fusers. Also have seen the lamps some, mostly thermostat. If it has many miles on it I'd just replace the fuser.
If the previous methid wont work..., Clear --> Density select --> Clear --> Density select is for service mode.
Check code 26-30 and set to 0 - CE mark support control OFF
Try surge arrest power source.