Iaqualink heater shuts down after a few minutes
Installed a new iaqualink with iPhone App. Ubit respondes, heats for a few minutes and then shuts down. Heater is a MininMax Pentair - LP. It is not the suspected problem. Water level seems fine. The pressure is on. Need to fine tune the iAqualink software
Pool & Spa - Zodiac - iQ904-P iAqualink Pool Only
Answers & Comments
Does the heater continue to fire if you run it in service mode? If so it probably is an Aqualink issue. I'd call the factory on that one and they should be able to get a rep or authorized service company to see what's happening.
If the heater is also shutting off in service mode the problem may be in the bypass ***'y. This is not an uncommon issue with the Minimax. Too much water is bypassing the heater and the water that does get in is staying there too long, triggering the high limit switch which will shut down the heater.