Intellitouch 9.3. Three years old, been fine till
Intellitouch 9.3. Three years old, been fine till now. Repeated Low Voltage Circuit Breaker trip of Electronics circuit. Seems to be related to rain/humidity although panel is not wet. Ideas???
Pool & Spa - Pentair - Intellitouch Pool or Spa Personality Kit - Single Body of...
Answers & Comments
I've been having the same problem - I don't have the complete solution but can tell you what I've been through so far. After 4 service calls and a visit from the local Pentair rep, they have replaced both circuit boards on the personality board. When they reconnected the spa-side remote, the electronics circuit tripped again. They are telling me I need to replace the spa-side remote, but I haven't since the repairs to date have cost me $1700 and they want another $700 to replace the spa-side remote. $2400 for a system that's 5 years old is ridiculous so for now I'm on hold, especially considering it may have been the spa-side remote all along. Don't know if your system includes the spa-side remote - if it does, disconnect it and see if the problem resolves itself, the remote may be the culprit.
And I dodged a bullet in that the breaker in question blew the day before and the day after we had a huge pool party when Blackhawks won the Cup!
I am a service tech in Houston, TX. Had the same issue and it was the spa side remote. $1,261.50 for a new spa commander installed plus tax, and $524.66 for the four function plus tax. I charged $100 for the diagnosis which took a total of 1/2hr. Thanks