Hi about error 3 please make sure first dc voltage comining fro power board to servo board check J8,J28, second encoder signal from the motor is not supplied check J2,J29, third check connection between main board and servo board J11,J1 best regards ashraf
Answers & Comments
Hi
about error 3 please make sure first dc voltage comining fro power board to servo board check J8,J28, second encoder signal from the motor is not supplied check J2,J29, third check connection between main board and servo board J11,J1
best regards
ashraf