M15 scanner Hi, I am service engineer for office automation products.I mistakely crosschecked the main pcb of M15 to M15i machine.After refitting old M15i main pcb ,it starts to scanner lock as scanner moving right side . I hope you will help in this issue soonest
That sounds more like the ribbon cable has some bad ends. remove the white ribbon cable from the board and see if some of the metal contacts are peeled back. I have seen that problem a few times. The ends of that cable are not made to be taken out and in very many times.
Answers & Comments
That sounds more like the ribbon cable has some bad ends. remove the white ribbon cable from the board and see if some of the metal contacts are peeled back.
I have seen that problem a few times. The ends of that cable are not made to be taken out and in very many times.
Most likely that ribbon cable needs replaced. It WILL cause that problem.