Model LG Lite 2 pilot is lit but the burners will not light. pressure switch is working corectly, on off togle switch is working, all wires are good(tested with ohm meter) what could be wrong?
Pool & Spa - Jandy - Lite 2 Natural Gas Pilot Light Heater
If this is a standing pilot you will want to check your voltage out put from the pilot. For this you will need a milivolt meter. The pilot should supply 500-700mv (1/2-3/4v) It only takes 200mv to open the pilot valve but needs another 300+ to open the main half of the gas valve. This would be the first thing I would check. If this is the problem you will need to replace the pilot assembly. If your getting the power you need from the pilot then it is probally your gas valve itself. Good luck.
Answers & Comments
If this is a standing pilot you will want to check your voltage out put from the pilot. For this you will need a milivolt meter. The pilot should supply 500-700mv (1/2-3/4v) It only takes 200mv to open the pilot valve but needs another 300+ to open the main half of the gas valve. This would be the first thing I would check. If this is the problem you will need to replace the pilot assembly. If your getting the power you need from the pilot then it is probally your gas valve itself. Good luck.