I had the following symptom: No power on, or only sporadic power on, power-on light blinking, etc. Problem was: Capacitor C202 & C203 (both 1000 uF, 16V) on the PS board had lost capacity, tested only approx 45 uF. Replaced, everything works fine now! Cost: 20 cent.
Answers & Comments
I had the following symptom: No power on, or only sporadic power on, power-on light blinking, etc.
Problem was: Capacitor C202 & C203 (both 1000 uF, 16V) on the PS board had lost capacity, tested only approx 45 uF. Replaced, everything works fine now! Cost: 20 cent.