This is what I read somewhere.... ok, then this means that one of your thermistors is shorted. There is a chill plate thermistor mounted to the bottom of your silver plate where the ice is formed, and there is a white thermistor mounted to the right side wall inside your bin. You can disconnect the chill plate thermistor and run a cycle to see if it will run without being connected. If the error goes away, you can leave the thermistor disconnected or replace it, either way the unit will continue to work.
If you disconnect the chill plate thermistor and it still doesn't work, then you need to replace your bin thermistor, you can't just disconnect this thermistor to get the unit working again.
Answers & Comments
This is what I read somewhere....
ok, then this means that one of your thermistors is shorted. There is a chill plate thermistor mounted to the bottom of your silver plate where the ice is formed, and there is a white thermistor mounted to the right side wall inside your bin. You can disconnect the chill plate thermistor and run a cycle to see if it will run without being connected. If the error goes away, you can leave the thermistor disconnected or replace it, either way the unit will continue to work.