Air in system-- most likely if common rail diesel ---problem in --pump--shut off solenoid ---pressure relief valve if conventional pump ---air inj pump ---stop solenoid ---rack stuck in idle position
Copyright © 2024 QA.XPDF.PUB - All rights reserved.
Answers & Comments
Air in system-- most likely
if common rail diesel ---problem in --pump--shut off solenoid ---pressure relief valve
if conventional pump ---air inj pump ---stop solenoid ---rack stuck in idle position