Have you had the generator stored with fuel in the carburettor since its last use if so the fuel goes bad and blocks up the main jet, remove the float bowl and clean out all the residue you can clean out the main jet with a suitable piece of wire
Copyright © 2024 QA.XPDF.PUB - All rights reserved.
Answers & Comments