Make sure you have turned the control knob to the "on" position. this is a milivolt system. the pilot make all the electricy to run the burner. make sure the pilot os blue and torch like not yellow and lazy. on the gas valve there are 3 wire connection point. one has a red wire one a white wire and the other lets say a black. with the thermostat turned down all the way jumper the red wire post to the one that doesn't have the white wire connected to is. this will by pass the thermostat. did it come on great check for loose connection didn't come on dang pilot generator may be weak and need to be replaced
Answers & Comments
Make sure you have turned the control knob to the "on" position. this is a milivolt system. the pilot make all the electricy to run the burner. make sure the pilot os blue and torch like not yellow and lazy. on the gas valve there are 3 wire connection point. one has a red wire one a white wire and the other lets say a black. with the thermostat turned down all the way jumper the red wire post to the one that doesn't have the white wire connected to is. this will by pass the thermostat. did it come on great check for loose connection didn't come on dang pilot generator may be weak and need to be replaced