Paper calibration has to be done , in offline go to test menu, select diag, select call paper , then it will ask remove paper (it will show around 4.5v to 5v) and then insert paper (it will show 0.1v to 0.9v) if the value is not come property then we need change the paper sensor . for that we need to remove the hammer assy
Answers & Comments
Paper calibration has to be done , in offline go to test menu, select diag, select call paper , then it will ask remove paper (it will show around 4.5v to 5v) and then insert paper (it will show 0.1v to 0.9v) if the value is not come property then we need change the paper sensor . for that we need to remove the hammer assy