Please help Hello, I have a true TSSU-48-18M-B sandwich prep table and has the following issue please help. Noticed it not working so it was already at 20 deg c I unplugged it and plugged it back in and the compressor kicked In and the fans went on and the temp dropped down to 2 deg then up to 4 deg then back to 2 (normal operation)then it goes up to 20 deg and then blows warm air??? Every time I unplug it then plug it back in it seems to do the exact thing??? I’ve checked to make sure the coil is clean (not perfect) Please help??
Make sure condenser coil is clean because it might cause overheating the compressor and thermal overoad will trip. Next is to check ampere rating on the compressor. It might be caused by sticking starting relays. You can base ampere rating in the sticker inside. All true units have it
Answers & Comments
Make sure condenser coil is clean because it might cause overheating the compressor and thermal overoad will trip. Next is to check ampere rating on the compressor. It might be caused by sticking starting relays. You can base ampere rating in the sticker inside. All true units have it