FIRST TEST THE GFCI RESET MUST ENGAGE WHEN POWERED WHEN YOU PRESS THE RESET YOU SHOULD FEEL A LIGHT CLICK IF SO THEN PRESS TEST YOU SHOULD HEAR IT TRIP, THIS IS GOOD UNIT SHOULD POWER AFTER YOU RESET IT IF IT DOES NOT RESET EITHER THE GFCI KNOWN AS THE GROUND FAULT CIRCUIT INTERRUPTER IS DETECTING MOISTURE INSIDE THE UNIT POSSIBLY SPRAYED AT THE OPENINGS PREVENTING USER FROM GETTING SHOCK,CHECK UNIT FOR MOISTURE GFCI SHOULD TRIP WHEN YOU POWER UNIT UP UNTIL MOISTURE IS GONE.IF NO MOISTURE DETECTED UNIT HAD A FLOW SWITCH INSIDE THAT CAN ALSO BE STUCK. SORRY FOR THE CAPS.
Answers & Comments
FIRST TEST THE GFCI RESET MUST ENGAGE WHEN POWERED WHEN YOU PRESS THE RESET YOU SHOULD FEEL A LIGHT CLICK IF SO THEN PRESS TEST YOU SHOULD HEAR IT TRIP, THIS IS GOOD UNIT SHOULD POWER AFTER YOU RESET IT IF IT DOES NOT RESET EITHER THE GFCI KNOWN AS THE GROUND FAULT CIRCUIT INTERRUPTER IS DETECTING MOISTURE INSIDE THE UNIT POSSIBLY SPRAYED AT THE OPENINGS PREVENTING USER FROM GETTING SHOCK,CHECK UNIT FOR MOISTURE GFCI SHOULD TRIP WHEN YOU POWER UNIT UP UNTIL MOISTURE IS GONE.IF NO MOISTURE DETECTED UNIT HAD A FLOW SWITCH INSIDE THAT CAN ALSO BE STUCK. SORRY FOR THE CAPS.