Hello...I have a Reddy propane heater model #RLP100. The problem I have is that after holding in the temp. button for 30 seconds on start up, the flame will go out. I replaced the thermocouple with the same results. My uneducated guess is, at worse, the valve kit is faulty. How can I be sure? The other side of the problem, at best, propane tank needs to be replenished. What say you to this?
Heating & Cooling - Reddy - Heater RLP100 Portable Forced Air Propane Heater with...
Answers & Comments
Try a little longer, sometimes it takes a full minute to heat the thermocouple. Check and make sure thermocouple is in flame. If all this is ok. then your going to have to change the valve.
If your incoming pressure is correct and , your thermocouple output is correct .
It should be the valve.
The valve has to have the right pressure against it to work properly.
Do not hit Accept unless you can give 100% feedback. Your satsifaction is very important to me. Let me know how it went.
Thank you for your time.
Do not do that, that is a safety and could get you and your family hurt.