Unplug the power supply give it about 30 second then plug the unit back in you should hear the servo motor resetting itself. If not you may have remove the side panels to inspect the magnetic boot and assembly to see if the servo motor is physically moving or not. Also check if the Drive belt it may have come off the fly wheel and large pulley assembly. If the belt is in place then to test the motor simply apply 12v DC to the motor leads then reverse the leads to to if their is movement. If not or hesitates replace motor if good we may have upper console problems.and will need to replaced. Call Icon Fitness @ 1-800-999-3756
Answers & Comments
Unplug the power supply give it about 30 second then plug the unit back in you should hear the servo motor resetting itself. If not you may have remove the side panels to inspect the magnetic boot and assembly to see if the servo motor is physically moving or not. Also check if the Drive belt it may have come off the fly wheel and large pulley assembly.
If the belt is in place then to test the motor simply apply 12v DC to the motor leads then reverse the leads to to if their is movement. If not or hesitates replace motor if good we may have upper console problems.and will need to replaced. Call Icon Fitness @ 1-800-999-3756