A-01-211 basically means there is master material under the position sensor while in standby. Referring to the manual open the master drawer and clamp rewind the master material back on it roll and close the lid/clamp. This allows the master unit to reset or to say "return home" action. Now open and re-insert the master material in its proper place. This is similar to A-34-218 code.
Answers & Comments
A-01-211 basically means there is master material under the position sensor while in standby. Referring to the manual open the master drawer and clamp rewind the master material back on it roll and close the lid/clamp. This allows the master unit to reset or to say "return home" action. Now open and re-insert the master material in its proper place. This is similar to A-34-218 code.