Ruud uhqa sill runs when i turn off t stat contactor test good and is not stuckhit breaker and back on and fan stops running goes on when t stat is turned on stays on till i trip breaker again i think it is groundhogs day lol
Heating & Cooling - Ruud - UAKA037 Air Conditioner
Your sentence is hard to understand because there is no punctuation. But, I think you are saying that the Outside unit is still running when the inside unit is off and the Thermostat indicates it should be off. If so, you have a stuck relay outside in the compressor/condenser unit. This is common. The contacts get hot and fuse themselves together. You will have to remove the cover on the unit outside to expose the relay. MAKE SURE THE BREAKER IS OFF. If you house is to code there will be a disconnect box on the wall just above the AC unit outside. PULL THE DISCONNECT> then use a flat head screw driver and slight pry the contacts apart. If they are fused very tight you may need to replace the relay. If they break free put every thing back together and you're done. If you this happens again soon you will need to replace relay.
Answers & Comments
Your sentence is hard to understand because there is no punctuation. But, I think you are saying that the Outside unit is still running when the inside unit is off and the Thermostat indicates it should be off. If so, you have a stuck relay outside in the compressor/condenser unit. This is common. The contacts get hot and fuse themselves together. You will have to remove the cover on the unit outside to expose the relay. MAKE SURE THE BREAKER IS OFF. If you house is to code there will be a disconnect box on the wall just above the AC unit outside. PULL THE DISCONNECT> then use a flat head screw driver and slight pry the contacts apart. If they are fused very tight you may need to replace the relay. If they break free put every thing back together and you're done. If you this happens again soon you will need to replace relay.