Starts runs for a minutes quits but if you keep pushing the start button it keeps running
Guardian 4000 has 147 hrs, starts right up runs for a few minutes than quits, but if you keep push ing the start buttion it will keep running? The start button inside or on generator,
Electrical Supplies - Onan - Cummins 4.0 KY-FA/26100 RV QG 4000 4000K Gasoline Generator...
Answers & Comments
You say Guardian that is Generac???? Then you indicate Onan 4.0KY. If it is a Onan and it stops after you release the button there are a couple of things. 1 st check the brushes, and polish the rotor slip rings, check the resisitance of the rotor, the electrical harness plugs are tight. The control requires a voltage feedback while cranking to engage the PCB run circuits, if all those check out you have a bad control board.