.CAUTION - Disconnect the power source from the brewer prior to the removal of any panel for the replacement or adjustment of any component. The water level can be adjusted. On almost all cw series coffee makers there is dip switch located on the circuit board behind the front panel. The dip switch(very small black or white) should not, not be in the on position. Making sure the switch is not in the on position(it should be swithced towards the set positon), put the front panel back on. Read and follow the instruction here after..
To increase a batch size. Press and hold the START or BREW switch until three clicks are heard. Release the switch (Failure to release the switch within two seconds after the third click causes the volume setting to be aborted and previous volume setting will remain in memory) and press it again one or more times. Each time the switch is pressed, two seconds are added to the brew time period. Allow the brew cycle to finish in order to verify that the desired volume has been achieved.
To decrease a batch size. Press and release the START or BREW switch once for every two-second interval to be removed from the total brew time period; then immediately press and hold down the START or BREW switch until three clicks are heard. Release the switch. (Failure to release the switch within two seconds after the third click causes the volume setting to be aborted and previous volume setting will remain in memory). Allow the brew cycle to finish in order to verify that the desired volume has been achieved
Answers & Comments
.CAUTION - Disconnect the power source from the brewer prior to the removal of any panel for the replacement
or adjustment of any component. The water level can be adjusted. On almost all cw series coffee makers there is dip switch located on the circuit board behind the front panel. The dip switch(very small black or white) should not, not be in the on position. Making sure the switch is not in the on position(it should be swithced towards the set positon), put the front panel back on. Read and follow the instruction here after..
To increase a batch size. Press and hold the START or BREW switch until three clicks are heard. Release
the switch (Failure to release the switch within two seconds after the third click causes the volume setting to
be aborted and previous volume setting will remain in memory) and press it again one or more times. Each
time the switch is pressed, two seconds are added to the brew time period. Allow the brew cycle to finish in
order to verify that the desired volume has been achieved.
To decrease a batch size. Press and release the START or BREW switch once for every two-second interval
to be removed from the total brew time period; then immediately press and hold down the START or BREW
switch until three clicks are heard. Release the switch. (Failure to release the switch within two seconds after
the third click causes the volume setting to be aborted and previous volume setting will remain in memory).
Allow the brew cycle to finish in order to verify that the desired volume has been achieved
http://www.manualslib.com/manual/219681/Bunn-Cwt-15-Aps.html?page=11#manual
The solenoid is leaking, replace and the problem will be gone.
water always stops flowing...but about a cup after the pot is full
Remove the front panel, you will find instructions on setting the volume.