Precor Error 30, 31, 32 and 33, Communications Error Probable Cause 1. Bad interconnect cable between upper PCA and lower PCA. 2. Interconnect cable is mistakenly plugged into the CSAFE connector at the upper PCA. 3. Elliptical 5.17 equipped with old software version 1.01 in upper and lower PCA. 4. Upper and lower PCAs have mismatched software. 5. Another component plugged onto the PCA is overloading the +5VDC power supply. 6. Bad lower PCA. 7. Bad upper PCA. Corrective Action
Test unit with a know good interconnect cable or test the interconnect cable for continuity. Replace interconnect cable if necessary.
Disconnect the interconnect cable from the CSAFE connector and attach to the proper position on the upper PCA.3.
Replace the upper and lower software of the 5.17 elliptical with the most current versions.4.
If one of the PCAs is found to have software version 1.01, replace it with the most current software version.
Disconnect all components from the upper and lower PCA leaving the >Test unit with a known good lower PCA. Replace the lower PCA if necessary.
Test unit with a known good upper PCA. Replace the upper PCA if necessary.
Answers & Comments
Precor Error 30, 31, 32 and 33, Communications Error Probable Cause 1. Bad interconnect cable between upper PCA and lower PCA.- Test unit with a know good interconnect cable or test the interconnect cable for continuity. Replace interconnect cable if necessary.
- Disconnect the interconnect cable from the CSAFE connector and attach to the proper position on the upper PCA.3.
- Replace the upper and lower software of the 5.17 elliptical with the most current versions.4.
- If one of the PCAs is found to have software version 1.01, replace it with the most current software version.
- Disconnect all components from the upper and lower PCA leaving the >Test unit with a known good lower PCA. Replace the lower PCA if necessary.
- Test unit with a known good upper PCA. Replace the upper PCA if necessary.
Precor Error Code 30 31 32 33
2. Interconnect cable is mistakenly plugged into the CSAFE connector at the upper PCA.
3. Elliptical 5.17 equipped with old software version 1.01 in upper and lower PCA.
4. Upper and lower PCAs have mismatched software.
5. Another component plugged onto the PCA is overloading the +5VDC power supply.
6. Bad lower PCA.
7. Bad upper PCA.
Corrective Action