FL Flood Condition FL flashes if any overfill condition occurs. This condition occurs when excessive water in the tub causes the overfill switch to trip. The control must realize that the trip was due to an overfill condition instead of a suds lack condition in order for FL to be displayed
With an overfill condition, the beeper repeats a warning every 10 seconds with no time-out. The pump is cycled in drain mode for 30 seconds on, 30 seconds off until the overfill switch resets or power is discontinued to the unit.
Answers & Comments
FL Flood Condition FL flashes if any overfill condition occurs. This condition occurs when excessive water in the tub causes the overfill switch to trip. The control must realize that the trip was due to an overfill condition instead of a suds lack condition in order for FL to be displayed
With an overfill condition, the beeper repeats a warning every 10 seconds with no time-out. The pump is cycled in drain mode for 30 seconds on, 30 seconds off until the overfill switch resets or power is discontinued to the unit.