When yanking on the pull cord to start engine
I own a Toro 6.5 hp mower. When yanking on the pull cord to start engine, the cord is yanked back into the cord housing into inside the mower. The yanking is done so fast, it prevents property starting of the mower. Eventually, the arm gets tired and hand gets sore.
What do you think is the problem?
Garden - Mtd - 22" Yard Machine Push Mower
Answers & Comments
Im guessing that you have started it before, so I guess , check that its not flooding ,pull air filter out see If you can see heaps of fuel in the bottom hole ,if you do take spark plug out pull cord a few times without holding start cable or you will catch on fire replace spark plug try starting ,no start still flooding take it to a lawn mower place ,float may have a hole in it , if not flooding, on the bottom of the cardy one brass nut , four holes find them clear then, start also a brass pipe going into the center of the carby is probable blocked