Hi Tripping the breaker is usually a bad heating element. You have to check each heating element to determine which element is bad (2 on and X2). Use an ohms meter and check the 2 elements on each boiler for a reading of between 12 and 16 ohms. If no reading that is the bad element. Its in an aluminum boiler so lubricate the end of the bolts(threads) before you try to remove them or they might break.
Answers & Comments
Hi
Tripping the breaker is usually a bad heating element. You have to check each heating element to determine which element is bad (2 on and X2). Use an ohms meter and check the 2 elements on each boiler for a reading of between 12 and 16 ohms. If no reading that is the bad element. Its in an aluminum boiler so lubricate the end of the bolts(threads) before you try to remove them or they might break.